鸭脖视频破解APP

  • <tr id='nwh2hr'><strong id='ibkm'></strong> <small id='dkmp'></small><button id='4iz5z'></button><li id='4cxu'> <noscript id='mky8'><big id='op0a'></big><dt id='j579'></dt></noscript></li></tr> <ol id='beals9'><option id='5deal'><table id='wq98j0'><blockquote id='ndk3mt'> <tbody id='7uwo'></tbody></blockquote></table></option></ol><u id='q72e2l'></u><kbd id='fd74ce'> <kbd id='q9jrql'></kbd></kbd>

    <code id='wm28'><strong id='sadb'></strong></code>

    <fieldset id='2p1i'></fieldset>
          <span id='d4yf0'></span>

              <ins id='ht1x'></ins>
              <acronym id='tx3mib'><em id='u99v2x'></em><td id='5grt50'><div id='3vplei'></div></td></acronym><address id='p1ydx'><big id='16f9o8'><big id='uxqi'></big><legend id='52is9f'></legend></big></address>

              <i id='8sf4'><div id='cmvksq'><ins id='l0eg'></ins></div></i>
              <i id='9c1r'></i>
            1. <dl id='ygj6'></dl>
              1. <blockquote id='ywfp'><q id='d3bj'><noscript id='lof5lf'></noscript><dt id='7wg1'></dt></q></blockquote><noframes id='uxpr'><i id='of2hen'></i>
                020-82185819
                690V浪涌保护器(一级、二级)

                690V浪涌保护器(一级、二级)

                产品特色

                ●作为第一级,第二级浪涌保护器防电涌保护使用

                ●690V避雷器优质元器件通过TUVUL等国际认证

                ●产品电压可选,从480V1000V交流

                ●应用于光伏发电,风力发电,发电站等交流设备的防雷

                咨询热线: 18928848650
                • 产品详情

                ■  产品用途

                690V电源防雷模块适用于工作电压为500~800V电源系统防雷保护。该产品广泛用于风力发电、光伏发电、工业厂矿等的电源系统,如各种箱变、变频器、汇流箱、逆变器、高低压配电柜以及其它各种重要且易遭受雷击的设备。

                ■产品特点

                ● 690V浪涌保护器选用优质压敏电阻,性能稳定可靠

                ● 失效检测指示、遥信报警接口

                ● 内置过热断路装置

                ●高雷电放电能力,ns级响应速度

                35mm 导轨安装

                ● 安装简单,维护方便

                ● 690V一级浪涌、二级浪涌

                ■  技术参数

                产品型号

                规格

                工作电压(Un

                最大持续运行电压(Uc

                标称通流容量(In

                最大通流容量(Imax

                电压保护水平(Up

                响应时间(tA

                工作温度

                LF M40/3P(690V)

                3PUc750V18mm

                500V~

                690V

                750V

                20kA

                40kA

                2.8kV

                25ns

                -40~+80

                LF M40/4P(690V)

                4PUc750V18mm

                20kA

                40kA

                2.8kV

                LF M80/3P(690V)

                3PUc750V36mm

                40kA

                80kA

                3.2kV

                LF M80/4P(690V)

                4PUc750V36mm

                40kA

                80kA

                3.2kV

                LF M100/3P(690V)

                3PUc750V36mm

                60kA

                100kA

                3.6kV

                LF M100/4P(690V)

                4PUc750V36mm

                60kA

                100kA

                3.6kV

                LF M40/690/3P

                3PUc1000V36mm

                690V~

                800V

                1000V

                20kA

                40kA

                3.4kV

                25ns

                -40~+80

                LF M40/690/4P

                4PUc1000V36mm

                20kA

                40kA

                3.4kV

                LF M80/690/3P

                3PUc1000V36mm

                40kA

                80kA

                3.8kV

                LF M80/690/4P

                4PUc1000V36mm

                40kA

                80kA

                3.8kV

                LF M100/690/3P

                3PUc1000V36mm

                60kA

                100kA

                4.2kV

                LF M100/690/4P

                4PUc1000V36mm

                60kA

                100kA

                4.2kV

                ■  安装说明

                ●690V配电系统浪涌安装前必须切断电源,严禁带电操作。

                ●建议在690V电涌保护器前端串联熔断器或自动断路器。

                ●安装时请根据安装示意图所示连接,其中L1L2L3为相线,N为中性线,PE为地线,切勿错接。安装完成后,合上自动断路器(熔断器)开关,检查工作状态是否正常。

                ●690V防雷模块在使用期间,应定期检测并查看故障显示窗口状态,当故障显示窗呈红色/蓝色(或带遥信的产品遥信端子输出报警信号)时,表示防雷模块发生故障,应及时维修或更换。

                ●并联式690V防雷器应并联安装(也可采用凯文接线方式),一般情况下,只需连接两个接线柱中的任意一个即可。连接线要求牢固可靠,且要求短、粗、直。

                ■安装示意图                      ■产品尺寸图

                1、18mm                                                                    118mm

                                                            

                2、36mm                                                                 236mm

                   



                18928848650
                7x24 小时咨询
                扫码咨询